MyHealth@Eu Laboratory Report
0.0.1 - qa-preview
150
This page is part of the MyHealth@Eu Laboratory Report (v0.0.1: QA Preview) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Official URL: http://fhir.ehdsi.eu/laboratory/StructureDefinition/Device-specimen-lab-myhealtheu | Version: 0.0.1 | |||
Draft as of 2024-04-18 | Computable Name: DeviceSpecimenMyHealthEu |
This profile defines how to represent a device in HL7 FHIR, when used as specimen subject, for the purpose of this guide.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Device | Device | |||||||||
identifier | O | 0..* | Identifier | Instance identifier
| ||||||
udiCarrier | O | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||
manufacturer | O | 0..1 | string | Name of device manufacturer
| ||||||
deviceName | ||||||||||
name | O | 1..1 | string | The name of the device
| ||||||
type | O | 0..1 | CodeableConcept | The type of device Binding: eHDSI Medical Device with exceptions (required)
| ||||||
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.type | required | EHDSIMedicalDeviceWithExceptionshttp://fhir.ehdsi.eu/laboratory/ValueSet/eHDSIMedicalDeviceWithExceptions from this IG |
Name | Flags | Card. | Type | Description & Constraints | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||||
identifier | O | 0..* | Identifier | Instance identifier
| ||||||
udiCarrier | OΣ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||
manufacturer | O | 0..1 | string | Name of device manufacturer
| ||||||
type | O | 0..1 | CodeableConcept | The type of device Binding: eHDSI Medical Device with exceptions (required)
| ||||||
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | required | EHDSIMedicalDeviceWithExceptionshttp://fhir.ehdsi.eu/laboratory/ValueSet/eHDSIMedicalDeviceWithExceptions from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||||
contained | 0..* | Resource | Contained, inline Resources | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||||
identifier | O | 0..* | Identifier | Instance identifier
| ||||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||||
udiCarrier | OΣ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||||
manufacturer | O | 0..1 | string | Name of device manufacturer
| ||||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
name | O | 1..1 | string | The name of the device
| ||||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||||
modelNumber | 0..1 | string | The model number for the device | |||||||
partNumber | 0..1 | string | The part number of the device | |||||||
type | O | 0..1 | CodeableConcept | The type of device Binding: eHDSI Medical Device with exceptions (required)
| ||||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
type | 0..1 | CodeableConcept | The type of the device version | |||||||
component | 0..1 | Identifier | A single component of the device version | |||||||
value | 1..1 | string | The version text | |||||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||||
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||||
location | 0..1 | Reference(Location) | Where the device is found | |||||||
url | 0..1 | uri | Network address to contact device | |||||||
note | 0..* | Annotation | Device notes and comments | |||||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||||
parent | 0..1 | Reference(Device) | The parent device | |||||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | EHDSIMedicalDeviceWithExceptionshttp://fhir.ehdsi.eu/laboratory/ValueSet/eHDSIMedicalDeviceWithExceptions from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from Device
Differential View
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Device | Device | |||||||||
identifier | O | 0..* | Identifier | Instance identifier
| ||||||
udiCarrier | O | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||
manufacturer | O | 0..1 | string | Name of device manufacturer
| ||||||
deviceName | ||||||||||
name | O | 1..1 | string | The name of the device
| ||||||
type | O | 0..1 | CodeableConcept | The type of device Binding: eHDSI Medical Device with exceptions (required)
| ||||||
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.type | required | EHDSIMedicalDeviceWithExceptionshttp://fhir.ehdsi.eu/laboratory/ValueSet/eHDSIMedicalDeviceWithExceptions from this IG |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||||
identifier | O | 0..* | Identifier | Instance identifier
| ||||||
udiCarrier | OΣ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||
manufacturer | O | 0..1 | string | Name of device manufacturer
| ||||||
type | O | 0..1 | CodeableConcept | The type of device Binding: eHDSI Medical Device with exceptions (required)
| ||||||
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | required | EHDSIMedicalDeviceWithExceptionshttp://fhir.ehdsi.eu/laboratory/ValueSet/eHDSIMedicalDeviceWithExceptions from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||||
contained | 0..* | Resource | Contained, inline Resources | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||||
identifier | O | 0..* | Identifier | Instance identifier
| ||||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||||
udiCarrier | OΣ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||||
manufacturer | O | 0..1 | string | Name of device manufacturer
| ||||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
name | O | 1..1 | string | The name of the device
| ||||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||||
modelNumber | 0..1 | string | The model number for the device | |||||||
partNumber | 0..1 | string | The part number of the device | |||||||
type | O | 0..1 | CodeableConcept | The type of device Binding: eHDSI Medical Device with exceptions (required)
| ||||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
type | 0..1 | CodeableConcept | The type of the device version | |||||||
component | 0..1 | Identifier | A single component of the device version | |||||||
value | 1..1 | string | The version text | |||||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||||
extension | 0..* | Extension | Additional content defined by implementations | |||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||||
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||||
location | 0..1 | Reference(Location) | Where the device is found | |||||||
url | 0..1 | uri | Network address to contact device | |||||||
note | 0..* | Annotation | Device notes and comments | |||||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||||
parent | 0..1 | Reference(Device) | The parent device | |||||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | EHDSIMedicalDeviceWithExceptionshttp://fhir.ehdsi.eu/laboratory/ValueSet/eHDSIMedicalDeviceWithExceptions from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from Device
Other representations of profile: CSV, Excel, Schematron