Unattributed Code Systems

Copyright Fragment

This fragment is available on index.html

This publication includes IP covered under the following statements.

Copyright and Registered Trademark Uses

External References

Type Reference Content
web tel:+49-30-1234567 telecom : +49-30-1234567 , info@universityhospital-berlin.eu
web fhir.ehdsi.eu
web health.ec.europa.eu IG © 2023+ MyHealth@Eu . Package myhealth.eu.fhir.laboratory#9.1.1-ci-build based on FHIR 4.0.1 . Generated 2026-04-09
web en.wikipedia.org Both Bundle.link and Bundle.entry.link are defined to support providing additional context when Bundles are used (e.g. HATEOAS ).
web wiki.ihe.net This is a metadata field from XDS/MHD .
web health.ec.europa.eu specifies a set of rules to be applied to HL7 FHIR to define how to represent a Laboratory Report for the European cross-borders exchange , coherently with the European eHN Guidelines (see the European eHealth - Key documents ).
web webgate.ec.europa.eu provides a representation of the Laboratory Result Content specified in the MyHealth@EU Functional Requirements 13.01 Create the MyHealth@EU Laboratory Result Report Content expressed as HL7 FHIR Logical Model.
web hl7.eu is derived for the HL7 Europe Laboratory Report HL7 FHIR IG fulfilling the MyHealth@EU Functional Requirements. More details in the MyHealth@EU Laboratory Models Overview page.
web hl7.eu The eHN guidelines is documented in the HL7 Europe Laboratory Report as HL7 FHIR Logical Models, including how this data set is implemented in HL7 FHIR; while this guide documents cross-borders reuqirements and associated profiles.
web hl7.eu Most of the design choices adopted by this guide are detailed in the parent guide HL7 EU Laboratory Report Design choices page .
web health.ec.europa.eu Specify a set of rules to be applied to HL7 FHIR to define how to represent a Laboratory Report for the European cross-borders exchange , coherently with the European eHN Guidelines (see the European eHealth - Key documents ).
web hl7.eu This guide is derived for the HL7 Europe Laboratory Report HL7 FHIR IG fulfilling the MyHealth@EU Functional Requirements (see the MyHealth@EU Laboratory Models Overview page)
web health.ec.europa.eu The corresponding eHN Guidelines: eHN Laboratory Result Guidelines (release 1) are available here
web hl7.eu The solution adopted by this guide - and detailed in the HL7 EU Laboratory Report Design choices page - balances the business requirement of Laboratory Report as legally signable document (i.e. as a HL7 FHIR document), with the expectation to get Lab Report by searching per DiagnosticReport. All this, taking into account the R5 DiagnosticReport design pattern where the DiagnosticReport - Composition relationship is directed from the DiagnosticReport to the Composition resource.
web ucum.org The UCUM codes, UCUM table (regardless of format), and UCUM Specification are copyright 1999-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. https://ucum.org/trac/wiki/TermsOfUse
Show Usage
web www.ilo.org This artifact includes content from International Standard Classification of Occupations (ISCO). ISCO is copyright International Labour Organization (ILO). Terms & Conditions in http://www.ilo.org/global/copyright/lang--en/index.htm
Show Usage
web webgate.ec.europa.eu MyHealth@EU logical models ( MyHealth@EU Laboratory Result Report Content ) refine the EHDS logical information models provided by the Xt-EHR project. These models use obligations on the logical models to highlight the elements identified by the MyHealth@EU Functional Requirements. Three types of obligations are defined based on the MyHealth@EU requirements:
web webgate.ec.europa.eu MyHealth@EU Laboratory Result Report Content
web health.ec.europa.eu eHealth Network Guideline on Laboratory Results
web www.xt-ehr.eu The MyHealthEuLabReport model refines EHDSLaboratoryReport . The report maps to multiple FHIR resources: BundleLabReportMyHealthEu , CompositionLabReportMyHealthEu , DiagnosticReportLabMyHealthEu , and ServiceRequestLabMyHealthEu .
web www.xt-ehr.eu The MyHealthEuLabObservation model refines EHDSLaboratoryObservation . It maps to ObservationResultsLaboratoryMyHealthEu .
web www.xt-ehr.eu The MyHealthEuLabServiceRequest model refines EHDSServiceRequest . It maps to ServiceRequestLabMyHealthEu .
web www.xt-ehr.eu The MyHealthEuLabSpecimen model refines EHDSSpecimen . It maps to SpecimenMyHealthEu .
web www.xt-ehr.eu The MyHealthEuPatient model refines EHDSPatient .
web www.xt-ehr.eu The MyHealthEuHumanName model refines EHDSHumanName .
web www.xt-ehr.eu The MyHealthEuAddress model refines EHDSAddress .
web www.xt-ehr.eu The MyHealthEuTelecom model refines EHDSTelecom .
web www.xt-ehr.eu The MyHealthEuHealthProfessional model refines EHDSHealthProfessional .
web www.xt-ehr.eu The MyHealthEuOrganisation model refines EHDSOrganisation .
web www.xt-ehr.eu The MyHealthEuDevice model refines EHDSDevice .
web www.xt-ehr.eu The MyHealthEuBodyStructure model refines EHDSBodyStructure .