This fragment is available on copyright.html
Error parsing IP fragment: unable to parse character reference ' Conditions in http://www.ilo.org/global/copyright/lang--en/index.htm'' (last text = ' ' at line 8 column 239
| Type | Reference | Content |
|---|---|---|
| web | tel:+49-30-1234567 | +49-30-1234567 |
| web | fhir.ehdsi.eu |
|
| web | health.ec.europa.eu |
IG © 2023+ MyHealth@EU
. Package myhealth.eu.fhir.laboratory#9.2.0 based on FHIR 4.0.1
. Generated 2026-10-22
|
| web | en.wikipedia.org | Both Bundle.link and Bundle.entry.link are defined to support providing additional context when Bundles are used (e.g. HATEOAS ). |
| web | wiki.ihe.net | This is a metadata field from XDS/MHD . |
| web | snomed.info | SNOMED CT Concept Domain Binding |
| web | siframework.org |
Quality Improvement and Clinical Knowledge (QUICK)
|
| web | code.europa.eu |
ObservationResultsLaboratoryMyHealthEu
: value[x]
is no longer limited to Quantity, Range and Ratio; all the result types of the base resource are allowed ( work item 5
).
|
| web | ucum.org |
The UCUM codes, UCUM table (regardless of format), and UCUM Specification are copyright 1999-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. https://ucum.org/trac/wiki/TermsOfUse
|
| web | health.ec.europa.eu | specifies a set of rules to be applied to HL7 FHIR to define how to represent a Laboratory Report for the European cross-border exchange , coherently with the European eHN Guidelines (see the European eHealth - Key documents ). |
| web | webgate.ec.europa.eu | provides a representation of the Laboratory Result Content specified in the MyHealth@EU Functional Requirements 13.01 Create the MyHealth@EU Laboratory Result Report Content expressed as HL7 FHIR Logical Model. |
| web | hl7.eu | is derived from the HL7 Europe Laboratory Report HL7 FHIR IG fulfilling the MyHealth@EU Functional Requirements. More details in the MyHealth@EU Laboratory Models Overview page. |
| web | hl7.eu | The eHN guidelines are documented in the HL7 Europe Laboratory Report as HL7 FHIR Logical Models, including how this data set is implemented in HL7 FHIR; while this guide documents cross-border requirements and associated profiles. |
| web | hl7.eu | Most of the design choices adopted by this guide are detailed in the parent guide HL7 EU Laboratory Report Design choices page . |
| web | health.ec.europa.eu | Specify a set of rules to be applied to HL7 FHIR to define how to represent a Laboratory Report for the European cross-border exchange , coherently with the European eHN Guidelines (see the European eHealth - Key documents ). |
| web | hl7.eu | This guide is derived from the HL7 Europe Laboratory Report HL7 FHIR IG fulfilling the MyHealth@EU Functional Requirements (see the MyHealth@EU Laboratory Models Overview page). |
| web | health.ec.europa.eu | The corresponding eHN Guidelines: eHN Laboratory Result Guidelines (release 1) are available here . |
| web | hl7.eu | The solution adopted by this guide - and detailed in the HL7 EU Laboratory Report Design choices page - balances the business requirement of Laboratory Report as legally signable document (i.e. as a HL7 FHIR document), with the expectation to get Lab Report by searching per DiagnosticReport. All this, taking into account the R5 DiagnosticReport design pattern where the DiagnosticReport - Composition relationship is directed from the DiagnosticReport to the Composition resource. |
| web | www.xt-ehr.eu | This guide is based on HL7 FHIR R4 (4.0.1), while the EHDS logical information models package it depends on ( xtehr.eu.ehds.models#1.0.0 ) is based on HL7 FHIR R5 (5.0.0). |
| web | hl7.eu |
The pattern
discriminator is valid in HL7 FHIR R4 but deprecated in R5, where value
is used instead. These slicings follow the HL7 Europe Laboratory Report
2.1.0 profiles that this guide imposes, which use pattern
for the same elements. They will be aligned when those profiles change.
|
| web | webgate.ec.europa.eu | MyHealth@EU logical models ( MyHealth@EU Laboratory Result Report Content ) refine the EHDS logical information models provided by the Xt-EHR project. These models use obligations on the logical models to highlight the elements identified by the MyHealth@EU Functional Requirements. The three obligation levels (Mandatory, Required and Optional), and how they are implemented, are described in the Introduction . |
| web | webgate.ec.europa.eu | MyHealth@EU Laboratory Result Report Content |
| web | health.ec.europa.eu | eHealth Network Guideline on Laboratory Results |
| web | www.xt-ehr.eu | EHDS Logical Information Models |
| web | www.xt-ehr.eu | The MyHealthEuLabReport model refines EHDSLaboratoryReport . The report maps to multiple FHIR resources: BundleLabReportMyHealthEu , CompositionLabReportMyHealthEu , DiagnosticReportLabMyHealthEu , and ServiceRequestLabMyHealthEu . |
| web | www.xt-ehr.eu | The MyHealthEuLabObservation model refines EHDSLaboratoryObservation . It maps to ObservationResultsLaboratoryMyHealthEu . |
| web | www.xt-ehr.eu | The MyHealthEuLabServiceRequest model refines EHDSServiceRequest . It maps to ServiceRequestLabMyHealthEu . |
| web | www.xt-ehr.eu | The MyHealthEuLabSpecimen model refines EHDSSpecimen . It maps to SpecimenMyHealthEu . |
| web | www.xt-ehr.eu | The MyHealthEuPatient model refines EHDSPatient . |
| web | www.xt-ehr.eu | The MyHealthEuHumanName model refines EHDSHumanName . |
| web | www.xt-ehr.eu | The MyHealthEuAddress model refines EHDSAddress . |
| web | www.xt-ehr.eu | The MyHealthEuTelecom model refines EHDSTelecom . |
| web | www.xt-ehr.eu | The MyHealthEuHealthProfessional model refines EHDSHealthProfessional . |
| web | www.xt-ehr.eu | The MyHealthEuOrganisation model refines EHDSOrganisation . |
| web | www.xt-ehr.eu | The MyHealthEuDevice model refines EHDSDevice . |
| web | www.xt-ehr.eu | The MyHealthEuBodyStructure model refines EHDSBodyStructure . |
eHN-to-specs.png
|
guide-content.png
|
lab-structure.png
|
tree-filter.png
|