MyHealth@Eu Laboratory Report
0.1.1 - trial-use 150

MyHealth@Eu Laboratory Report - Local Development build (v0.1.1) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

ValueSet: eHDSI Laboratory Technique with exceptions

Official URL: http://fhir.ehdsi.eu/laboratory/ValueSet/eHDSILabTechniqueWithExceptions Version: 0.1.1
Standards status: Trial-use Maturity Level: 2 Computable Name: EHDSILabTechniqueWithExceptions

Copyright/Legal: The Value Set incorporates SNOMED CT®, used by permission of the International Health Terminology Standards Development Organisation, trading as SNOMED International. SNOMED CT was originally created by the College of American Pathologists. SNOMED CT is a registered trademark of the International Health Terminology Standards Development Organisation, all rights reserved. For further information on the use of SNOMED CT, including translations, implementers of MyHealth@EU should review usage terms or directly contact SNOMED International: info@snomed.org.

This Value Set is used to encode laboratory technique for the result measurement. It also includes exceptional values.

References

Logical Definition (CLD)

This value set includes codes based on the following rules:

 

Expansion

This value set contains 145 concepts

SystemCodeDisplay (en)DefinitionJSONXML
http://terminology.hl7.org/CodeSystem/v3-NullFlavor  OTHother

**Description:**The actual value is not a member of the set of permitted data values in the constrained value domain of a variable. (e.g., concept not provided by required code system).

Usage Notes: This flavor and its specializations are most commonly used with the CD datatype and its flavors. However, it may apply to *any* datatype where the constraints of the type are tighter than can be conveyed. For example, a PQ that is for a true measured amount whose units are not supported in UCUM, a need to convey a REAL when the type has been constrained to INT, etc.

With coded datatypes, this null flavor may only be used if the vocabulary binding has a coding strength of CNE. By definition, all local codes and original text are part of the value set if the coding strength is CWE.

http://terminology.hl7.org/CodeSystem/v3-NullFlavor  UNKunknown

**Description:**A proper value is applicable, but not known.

Usage Notes: This means the actual value is not known. If the only thing that is unknown is how to properly express the value in the necessary constraints (value set, datatype, etc.), then the OTH or UNC flavor should be used. No properties should be included for a datatype with this property unless:

  1. Those properties themselves directly translate to a semantic of "unknown". (E.g. a local code sent as a translation that conveys 'unknown')
  2. Those properties further qualify the nature of what is unknown. (E.g. specifying a use code of "H" and a URL prefix of "tel:" to convey that it is the home phone number that is unknown.)
http://terminology.hl7.org/CodeSystem/v3-NullFlavor  UNCun-encoded

Description: The actual value has not yet been encoded within the approved value domain.

Example: Original text or a local code has been specified but translation or encoding to the approved value set has not yet occurred due to limitations of the sending system. Original text has been captured for a PQ, but not attempt has been made to split the value and unit or to encode the unit in UCUM.

Usage Notes: If it is known that it is not possible to encode the concept, OTH should be used instead. However, use of UNC does not necessarily guarantee the concept will be encodable, only that encoding has not been attempted.

Data type properties such as original text and translations may be present when this null flavor is included.

http://snomed.info/sct  115341008Total measurement
http://snomed.info/sct  1179120009Fractionation technique (qualifier value)
http://snomed.info/sct  1259936007Enzyme-linked fluorescence assay technique
http://snomed.info/sct  1285484006Touch preparation cytology technique
http://snomed.info/sct  1287497009Screening technique
http://snomed.info/sct  1303773004Fluorescence in situ hybridisation technique
http://snomed.info/sct  1303854007Hybridization protection technique (qualifier value)
http://snomed.info/sct  1303855008Comparative genomic hybridization technique (qualifier value)
http://snomed.info/sct  1303857000Immunoradiometric technique
http://snomed.info/sct  1303969007EA (erythrocyte antibody) rosette technique
http://snomed.info/sct  1303975003Disk diffusion technique (qualifier value)
http://snomed.info/sct  1303991000Viscoelastic coagulation technique (qualifier value)
http://snomed.info/sct  1304081004Light transmission aggregometry technique
http://snomed.info/sct  1304086009Whole blood aggregometry technique (qualifier value)
http://snomed.info/sct  1304163000Isoelectric focusing electrophoresis technique (qualifier value)
http://snomed.info/sct  1304253004Coulometry technique (qualifier value)
http://snomed.info/sct  1304288004Proportion method on 7H11 agar technique
http://snomed.info/sct  1304289007Proportion method on 7H10 agar technique
http://snomed.info/sct  1306386000TEG (thromboelastography) technique
http://snomed.info/sct  1306388004Rotational thromboelastometry technique (qualifier value)
http://snomed.info/sct  1306411001Sonic estimation of elasticity via resonance sonorheometry technique (qualifier value)
http://snomed.info/sct  1306896004Automated liquid-based media for slow growing Mycobacteria technique (qualifier value)
http://snomed.info/sct  1306897008Modified agar proportion method for slow growing Mycobacteria
http://snomed.info/sct  1306902009Resonance thromboelastography technique (qualifier value)
http://snomed.info/sct  1306906007Hemocytometry counting technique (qualifier value)
http://snomed.info/sct  1331920002Automated cytology stain with automated cytocentrifugation technique
http://snomed.info/sct  258005004Accelerometry
http://snomed.info/sct  258010000Catheter tip manometry
http://snomed.info/sct  258013003Conventional manometry
http://snomed.info/sct  258014009Dilution and colorimetry
http://snomed.info/sct  258018007Drainage bottle measurement
http://snomed.info/sct  258019004Drainage measurement
http://snomed.info/sct  258037003Immunoradiometry
http://snomed.info/sct  258084003Weighing of swabs
http://snomed.info/sct  258118009Suction drainage measurement
http://snomed.info/sct  262062007Power output
http://snomed.info/sct  66701000052100Fluorescent enzyme immunoassay technique (qualifier value)
http://snomed.info/sct  66721000052106Recombinant immunoblot assay technique (qualifier value)
http://snomed.info/sct  702659008Automated count
http://snomed.info/sct  702660003Test strip
http://snomed.info/sct  702663001Manual count
http://snomed.info/sct  702664007Immunological method (qualifier value)
http://snomed.info/sct  702665008Cytology stain
http://snomed.info/sct  702666009Cytology
http://snomed.info/sct  702667000Clearance calculation formula (qualifier value)
http://snomed.info/sct  702668005Modification of diet in renal disease formula
http://snomed.info/sct  702669002Direct assay
http://snomed.info/sct  702673004Deoxyribonucleic acid probe
http://snomed.info/sct  702674005Nucleic acid hybridization probe
http://snomed.info/sct  702675006Probe with target amplification
http://snomed.info/sct  702872006Detection limit equal to or less than 20 mg/L
http://snomed.info/sct  702873001Calculation technique (qualifier value)
http://snomed.info/sct  702945004Estimated from glycated haemoglobin
http://snomed.info/sct  702946003Coagulation technique
http://snomed.info/sct  702947007Corrected for nucleated erythrocytes
http://snomed.info/sct  703436002Detection limit equal to or less than 0.005 mIU/L
http://snomed.info/sct  703437006Detection limit equal to or less than 0.01 ng/mL
http://snomed.info/sct  703438001Detection limit equal to or less than 0.05 mIU/L
http://snomed.info/sct  703439009Detection limit equal to or less than 1.0 ng/dL
http://snomed.info/sct  703440006Detection limit equal to or less than 3.47 pmol/L
http://snomed.info/sct  703442003Gradient strip susceptibility test
http://snomed.info/sct  703444002Fluorescent immunoassay
http://snomed.info/sct  703445001Ion selective electrode measurement
http://snomed.info/sct  703446000Immunoblot assay
http://snomed.info/sct  703448004Latex agglutination test
http://snomed.info/sct  703449007Radioimmunoassay
http://snomed.info/sct  703450007Electrophoresis
http://snomed.info/sct  703452004Electrical impedance technique
http://snomed.info/sct  703462006Cockcroft-Gault formula (qualifier value)
http://snomed.info/sct  703463001Calculated from oxygen partial pressure
http://snomed.info/sct  703488009Coagulation 1:1 saline mixture technique (qualifier value)
http://snomed.info/sct  703497008Calculated from signal to cutoff ratio
http://snomed.info/sct  703505007Clearance calculation relative to 1.73 square meters body surface area (qualifier value)
http://snomed.info/sct  703506008Clearance calculation relative to 1.73 square meters body surface area and adjusted for African race
http://snomed.info/sct  703507004Clearance calculation relative to 1.73 square meters body surface area and adjusted for non-African race (qualifier value)
http://snomed.info/sct  70531000052106Agarose gel electrophoresis technique (qualifier value)
http://snomed.info/sct  70581000052105Capillary electrophoresis technique (qualifier value)
http://snomed.info/sct  707682000Adjusted measurement technique (qualifier value)
http://snomed.info/sct  707683005Adjusted for diabetes technique (qualifier value)
http://snomed.info/sct  707684004Adjusted for multiple gestations technique (qualifier value)
http://snomed.info/sct  707685003Adjusted for sex hormone binding globulin technique (qualifier value)
http://snomed.info/sct  707687006Adjusted for weight technique (qualifier value)
http://snomed.info/sct  707688001Adjusted to patients actual temperature technique (qualifier value)
http://snomed.info/sct  707689009Adjusted to pH 7.4 technique (qualifier value)
http://snomed.info/sct  707690000Corrected for albumin technique (qualifier value)
http://snomed.info/sct  707691001Corrected for background technique (qualifier value)
http://snomed.info/sct  707692008Corrected for glucose technique (qualifier value)
http://snomed.info/sct  707693003Corrected for total protein technique (qualifier value)
http://snomed.info/sct  707694009Saturation adjusted to 0.5 technique (qualifier value)
http://snomed.info/sct  707695005Standard base excess technique
http://snomed.info/sct  707696006Standard base excess adjusted for oxygen saturation technique
http://snomed.info/sct  707698007Ion selective membrane electrode output adjusted to pH 7.4
http://snomed.info/sct  707699004Helium single breath output adjusted for hemoglobin (qualifier value)
http://snomed.info/sct  707700003Automated count output corrected for nucleated erythrocytes (qualifier value)
http://snomed.info/sct  707701004Calculated and adjusted for body weight (qualifier value)
http://snomed.info/sct  707702006Calculated output adjusted to standard (qualifier value)
http://snomed.info/sct  708062001Immunodiffusion
http://snomed.info/sct  708063006Immunoelectrophoresis
http://snomed.info/sct  708064000Immunofixation
http://snomed.info/sct  708065004Pulse oximetry
http://snomed.info/sct  708069005Chromogenic technique (qualifier value)
http://snomed.info/sct  708076000Kleihauer-Betke technique
http://snomed.info/sct  708077009Infrared spectroscopy
http://snomed.info/sct  708532004Platelet aggregation technique (qualifier value)
http://snomed.info/sct  719677008Direct immunocytochemical technique (qualifier value)
http://snomed.info/sct  723204004Base delta calculation technique (qualifier value)
http://snomed.info/sct  723205003Anion gap calculation technique (qualifier value)
http://snomed.info/sct  723206002Anion gap based on sodium, chloride and bicarbonate ions calculation technique (qualifier value)
http://snomed.info/sct  723207006Anion gap based on sodium, potassium, chloride and bicarbonate ions calculation technique (qualifier value)
http://snomed.info/sct  723208001Base excess calculation technique (qualifier value)
http://snomed.info/sct  723209009Base deficit calculation technique (qualifier value)
http://snomed.info/sct  726447007Kaolin induced coagulation technique (qualifier value)
http://snomed.info/sct  726451009Signal amplification technique (qualifier value)
http://snomed.info/sct  726748001Radioallergosorbent testing technique (qualifier value)
http://snomed.info/sct  737102004Automated test strip technique (qualifier value)
http://snomed.info/sct  737103009Manual test strip technique
http://snomed.info/sct  737105002Glomerular filtration rate calculation technique (qualifier value)
http://snomed.info/sct  737106001Chromosome-specific cell free deoxyribonucleic acid dosage calculation technique (qualifier value)
http://snomed.info/sct  737107005Immunoglobulin G index calculation technique
http://snomed.info/sct  737108000Immunoglobulin G synthesis rate calculation technique
http://snomed.info/sct  737109008Free thyroxine index calculation technique
http://snomed.info/sct  737110003Free androgen index calculation technique (qualifier value)
http://snomed.info/sct  737111004Coagulation factor assay technique (qualifier value)
http://snomed.info/sct  737112006Diatomaceous earth induced coagulation technique
http://snomed.info/sct  737113001International normalized ratio calculation technique (qualifier value)
http://snomed.info/sct  737114007Factor substitution technique
http://snomed.info/sct  737115008Hexagonal phase phospholipid technique (qualifier value)
http://snomed.info/sct  737116009Lupus sensitive technique (qualifier value)
http://snomed.info/sct  737117000Lupus sensitive percent correction technique
http://snomed.info/sct  737118005Lupus sensitive excess phospholipid technique
http://snomed.info/sct  737119002Dilute Russell viper venom percent correction technique
http://snomed.info/sct  737120008Dilute Russell viper venom excess phospholipid technique
http://snomed.info/sct  737537008Calculation based on general population risk (qualifier value)
http://snomed.info/sct  737538003Calculation based on maternal age (qualifier value)
http://snomed.info/sct  741815002Measurement technique with detection limit equal to or less than 1.0 mg/L
http://snomed.info/sct  758639009Patient result divided by control result calculation technique
http://snomed.info/sct  761997001Epinephrine induced coagulation technique (qualifier value)
http://snomed.info/sct  761998006Percent correction technique (qualifier value)
http://snomed.info/sct  761999003Lupus sensitive with 1:1 pooled normal plasma technique (qualifier value)
http://snomed.info/sct  767095001Direct immunofluorescence technique (qualifier value)
http://snomed.info/sct  767096000Indirect immunofluorescence technique
http://snomed.info/sct  897048005Bioimpedance spectroscopy

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept